High accuracy resonant pressure sensor

In addition to providing the performance and packaging improvements available with TERPS, the RPS/DPS 8100 product line takes advantage of best practices to offer a wide range of pressure and electrical connections to enable a level of customization for your specific requirements never before available in the performance class of this sensor.

The combination of the power of the TERPS technology and the quality, reliability and flexibility of the RPS/DPS 8100 Series offers a truly unique solution for high accuracy and high stability pressure measurement requirements.



Product Overview
Features
  • High precision, ±0.01% FS over compensated temperature range
  • High stability, ±50 ppm FS/year (typical)
  • Wide temperature range, up to -55 to +125°C (-67 to 257°F)
  • Multiple output configurations, RS232, RS485, USB 2.0, CANBus, Frequency & Diode (TTL)
  • Wide selection of pressure and electrical connections to suit specific requirements
  • Low acceleration effects
Measurement

Base pressure ranges

  • 0 to 2 bar (0 to 30 psi) absolute
  • 0 to 3.5 bar (0 to 50 psi) absolute

Calibrated ranges

  • Barometric: Up to 1.3 bar (18 psi) with minimum span of 350 mbar (5 psi)
  • 低压:2条(30 psi)与最低span of 0.5 bar (7 psi)
  • High pressure: Up to 3.5 bar (50 psi) with minimum span of 1 bar (14 psi)

Note: Values in psi are approximate.

Alternative barometric ranges are available on request.

Higher pressure ranges are available in the RPS/DPS 8000 series.

Overpressure2X FS

Pressure containment7 bar (100 psi)

Performance

There are two levels of performance specification:

  • Standard
  • Improved

Specifications include combined effects of non-linearity, hysteresis, repeatability and temperature errors over the compensated temperature range and calibrated pressure range.

Physical specifications

Long term stabilityStandard: ±0.02% FS/annum max. Improved: ±0.01% FS/annum max. (±0.005% FS typical) Note: Unless otherwise specified, specifications are at the reference conditions of 25°C (77°F) ±5°C (±9°F)

Orientation (g) sensitivityLess than 0.05 mbar/g

Storage temperature rangeAs compensated temperature range

Operating temperature rangeAs compensated temperature range (restricted by some electrical connector options)

Pressure mediaNon-condensing dry gases compatible with 316L stainless steel, silicon, silicon dioxide, Fluorosilicon RV adhesive and glass

Ingress protectionSee electrical connector section

VibrationBS EN 60068-2-6 (2008) sine sweeps 5 Hz to 2 kHz, levels to 20gn BS EN 60068-2-64 random 10 Hz to 2kHz to 4gn RMS for 1 hour each axis Less than 0.02% FS effect at any time

ShockDO-160E 9 (figure 7.2) 20 gn 11 ms terminal saw-tooth profile Negligible calibration change

Pressure connectorPressure connector should be one of:

  • G1/4 female
  • G1/4 male flat
  • G1/4 male 60° internal cone
  • G1/8 male 60° internal cone
  • 1/4 NPT female
  • 1/4 NPT male
  • 1/8 NPT male
  • M20 x 1.5 male (3mm bore)
  • M14 x 1.5 60° internal cone
  • M12 x 1 internal cone
  • 7/16-20 UNJF male 74° external cone
  • G1/2 male
  • G1/4 quick connect
  • 1/2 NPT male
  • G1/4 male flat long
  • 7/16-20 UNF female
  • Depth cone (G1/4 female)
  • 7/16-20 UNF male short flat
  • 3/8-24 UNJF
  • 1/4 VCR female
  • 1/4 VCR male
  • M12 B/head with 4 mm barb

Datasheet

Datasheets -RPS8100 /DPS8100



Contact Us | Support

For more information on Druck products or to reach a member of your local Druck team please click >here

You can contact the Druck Support Team >here


Get in touch with an expert.