Druck Elite Portfolio

Druck's Elite Range ofmultifunction calibratorsprovide an all-in-one solution for your pressure measurement and generation needs. The Market leadingDPI620Gmultifunction process calibrator and HART /Foundation Fieldbus communicator features a modular design that enables expansion over time.

The Druck GENii advanced modular calibration system comprises of four possible system components to provide the multifunctionality to perform duties formerly requiring a wide range of different instruments. These system components are:

  • DPI620G– Electrical/Multi-function calibrator, HART/ Fieldbus communicator
  • PM620/PM620T- Interchangeable pressure modules (**all ranges from 0.7bar/10psi up to 20 bar/300 psi compatible with the PV624)
  • MC620G- Pressure module carrier
  • PV62XG(including thenew PV624) - Pressure generating base stations.

This user selectable flexible system allows the choice of multiple DPI620G models to be used as a standalone electrical/multi-function calibrator, as a pressure reference with the addition of a pressure module carrier and pressure modules or as a self-contained pressure calibrator with a pressure base station and a pressure module.

Download all product manuals and software on theDruck Portal.

GENii Advanced Modular Calibration System Overview
DPI620G Series - Multifunction Calibrator

Druck's DPI620G combines an advanced multi-function calibrator and HART/Foundation Fieldbus communicator with world-class pressure measurement and generation. ATEX, IECEx and ETL approved intrinsically safe versions are available for use in hazardous areas.

频率和坦佩,这超小型电子rature calibrator with full HART communicator and optional Foundation Fieldbus communicator provides simultaneous measurement and source capabilities for the setup, testing and calibration of most types of process instruments including transmitters, transducers, gauges/indicators, switches, proximity detectors, counters, RTDs, thermocouples and valve positioners.

DPI620G Series Product Image
PV62XG - Pressure Generation Stations

With four pressure generating base stations, offering efficient pressure generation up to 1,000 bar, with optionalsafe and hazardous environment configurations:

  • ThePV621, a pneumatic pressure generator for pressures 95% vacuum to20 bar (300 psi)
  • ThePV622, a pneumatic pressure generator for pressures 95% vacuum to100 bar (1,500 psi)
  • ThePV623, a hydraulic pressure generator for pressures up to1,000 bar (15,000 psi)
  • ThePV624,a portable hybrid pressure controller, combining manual and automatic technologies, up to20 bar (300 psi)

Each pressure station is designed forstand-alone operationas a pressure generator and can replace conventional hand pumps to provide greater efficiency and ease of use. They can also be used on the workbench as comparators. Combining any of the pressure stations with a PM620 pressure module and the DPI620 calibrator createsa uniquely capable, self-contained pressure calibrator.

Druck PV624 Product Image
PM620 - Interchangeable Pressure Modules

ThePM620is the latest development indigital output sensor technology将允许一定数量的关键创新pressure re-ranging of compatible equipment. A simple screw fit makes both the pressure and electrical connectionswithout the need for tools, sealing tape, cables, or plugsand digital characterization allowsinterchangeability without set-up or calibration. The PM 620 is also available in an intrinsically safe version, thePM 620-IS, for use in hazardous environments.

Features include:

  • Fully interchangeable with no need for set-up or calibration
  • Simple screw fit - hand tight no tools required
  • Ranges from 25 mbar to 1,000 bar (10 inH2 O to 15,000 psi)
  • Accuracy from 0.005% FS
  • Safe and Hazardous area Versions available
  • Pressure ranges from -14.5 to 15,000 psi
  • Gauge or absolute pressures
  • IS model is ATEX and IEC approved Intrinsically Safe
Druck PM620 Pressure Modules
PM620T - Interchangeable High-Accuracy Pressure Modules

PM620 now incorporates our unique range ofTERPS resonant silicon pressure sensor technology,PM620Tand thePM620TSintrinsically safe version. Providing up to four times greater stability and higher accuracy than current pressure measurement technologies.

Features include:

  • Total uncertainty from 0.0125% FS
  • Temperature-compensated accuracy from -10°C to 50°C (-14°F to 122°F)
  • Simple screw fit - hand tight no tools required
  • Ranges from 1.2 bar to 100 bar (17.5 psi to 1500 psi)
  • Compatibility with pressure calibrators such as DPI612 and DPI620G/DPI620G-IS series
  • Fully interchangeable with no need for set-up or calibration
Druck PM620T Product Image
MC620G - Pressure Module Carrier

TheMC620module carrier attaches to the head of the DPI620G to provide two independent pressure measurement channels. These can be fitted with any PM620 pressure module from 25 mbar to 1,000 bar (10 inH2 O to 15,000 psi). Asimple screw fit means no tools are requiredand ensures both a high integrity pressure seal and a reliable digital interface. Even thepressure adapters are interchangeableand only require a finger tight fit. The carrier is designed for pressure safety andwill automatically seal if a module is not fitted or if the user attempts to remove it.

Features include:

  • 2 independent pressure channels
  • Simple to re-range
  • Pressure protection
  • Safe and Hazardous (IS) versions available

druck mc620 pressure module carrier for dpi620G
DPI620G - Accessories

IO620-AC- Replacement AC voltage measurement probe Attaches to the DPI620G, 30 V sockets to provide 300 VAC true rms measurement. Is supplied as standard with all new DPI620G

IO620-CASE-1- Carrying case Protective carrying case with belt loop, shoulder strap and large detachable pocket for test leads and accessories

IO620-CASE-2- System carrying case Protective carrying case for system components including the DPI620G, MC620G, PM620 modules, test leads, hose and adaptors

IO620-CHARGER- Battery charging station External battery charging station allows a spare battery to be charged independently of the DPI620G for minimum instrument downtime. Power is provided by the standard mains adaptor (P/N I0620-PSU). A complete charge cycle takes approximately 6.5 hours. The charging station can be connected to a USB port to provide a top-up charge (full charge in 13 hours)

IO620-USB-PC- USB cable Connects the DPI620G or DPI620G-IS to a PC

IO620-IDOS-USB- IDOS to USB converter Allows connection of an IDOS universal pressure module to the DPI620G. P/N IO620-USB-PC is also required to connect the converter to the DPI620G USB port. (not compatible with DPI620G-IS)

IO620-USB-RS232- USB to RS 232 cable Connects the DPI620G to an RS 232 interface (not compatible with DPI620G-IS)

dpi620g accessories druck multifunction calibrator
Keep your Druck instrument up-to-date!
New customer portal making your life easier

Make sure your pressure calibrator is up-to-date with the latest features! Here you can check the latest versions of the supporting files (firmware, documents and software)

Login

Druck Product Obsolescence Notice

UPS-III- This product has been discontinued. Druck recommends the DPI802 as the alternative product option. Please contact a Druck specialist for immediate assistance.UPS-III-IS- This product has been discontinued. Druck recommends the DPI620G-L-IS as an alternative product option. Please contact a Druck specialist for immediate assistance.

See For Yourself

Contact us to schedule your own on-site or virtual demo to understand the full capabilities of theDruckline of multifunction calibrators.

Request a Demo|Request a Quote|Contact Druck

Need to upgrade your legacy Druck equipment?
Replacement Options for Legacy Druck Multifunction Calibrators

Legacy Model Number
End of Service & Repair Support
Calibration Support
Recommended Replacement
DPI320/325
2013
Calibration currently supported
DPI620G or PM620 or PV622G (Pneumatic)
DPI330/335
2013
Calibration currently supported
DPI620G or PM620 or PV623G
MCX (All models) / TRX (All models, including T460)
No service or repair available
Calibration currently supported
DPI620G (Genii) or DPI880
DPI620/620-CE
2018
Calibration currently supported
DPI620G (Genii)
DPI620IS & DPI620IS-CE
2019
Calibration currently supported
DPI620G-IS Series (Genii)
HTP1
No service or repair available
No calibration support available
PV212-22 or PV212-23
PRV12-HTP1
No service or repair available
No calibration support available
PRV212-1, PRV212-2, PRV212-3, PRV212-4, or PRV212-5
PRV12-PV212
No service or repair available
No calibration support available
PRV212-1, PRV212-2, PRV212-3, PRV212-4, or PRV212-5
1S-01-0657
No service or repair available
No calibration support available
PV212A121M2038-1
1S-01-0942
No service or repair available
No calibration support available
PV212A121M2038-2
1S-01-0671
No service or repair available
No calibration support available
PV212A121M2038-3
1S-01-0886-NEW
No service or repair available
No calibration support available
PV212A121M2038-4
1S-01-0736
No service or repair available
No calibration support available
PV212A121M2038-5
201-978
No service or repair available
No calibration support available
PV212A121M2038-6
PV212-700
No service or repair available
No calibration support available
PV212-22-P
PV212-22-0
No service or repair available
No calibration support available
PV212-22-P
PV212
No service or repair available
No calibration support available
PV212-22-P
PV212-25-0
No service or repair available
No calibration support available
PV212-22-P
PV212-HP-700
No service or repair available
No calibration support available
PV212-22-TK-B
PV212-22-0HA
No service or repair available
No calibration support available
PV212-22-TK-N
PV212-HP
No service or repair available
No calibration support available
PV212-22-TK-B
PV212-25-0HA
No service or repair available
No calibration support available
PV212-22-TK-N
PV212-DPI104
No service or repair available
No calibration support available
PV212-22-104-B or PV212-22-104-N
PV212-DPI104-HP
No service or repair available
No calibration support available
PV212-23-104-B or PV212-23-104-N
PV212-DPI104S
No service or repair available
No calibration support available
PV212-22-104S-B or PV212-22-104S-N
PV212-DPI104S-HP
No service or repair available
No calibration support available
PV212-23-104S-B or PV212-23-104S-N
1 s - htp1 - 700 oem
Contact Druck for unit assessment
No calibration support available
PV212-22-P
1 s - htp1 - 700 oem-US
Contact Druck for unit assessment
No calibration support available
PV212-22-P
1S-HTP1-1000-OEM
Contact Druck for unit assessment
No calibration support available
PV212-23-P
1S-HTP1-1K-OEM-US
Contact Druck for unit assessment
No calibration support available
PV212-23-P
1 s-htp1-700
Contact Druck for unit assessment
No calibration support available
PV212-22-TK-B
1S-HTP1-1000
Contact Druck for unit assessment
No calibration support available
PV212-23-TK-B


Get in touch with an expert.

Your request has been submitted.
Thank you for your interest. A specialist will be in touch with you shortly.