TDLAS
Moisture Analyzers

Panametrics, a Baker Hughes business, offersTunable Diode Laser Absorption Spectroscopy (TDLAS)to measure the moisture concentration in common gases. The Panametrics TDLAS portfolio, featuring theAurora product line, consists of industrial analyzers with intuitive interfaces and patented technology for superior performance.

These tunable diode laser analyzers are known for theirfast and accurate response, able toanalyze moisture from 2 to 5000 PPMv.Ourpatented calibration schemeallows for variations in background gas that would result in error conditions in other analyzers.

Requiring no regular recalibration,our TDLAS-equippedmoisture analyzersoffer our customers a low cost of ownership.

Aurora is available in these three configurations:

  • Auroraprovidesimmediate responseto process upsets and quick dry down upon recovery.
  • Aurora TransPortoffers TDLAS performance in arugged portable analyzer, whether onbattery or online power.
  • Aurora RMrack-mount analyzer uses TDLAS to accurately measure moisture in a variety of background gases.
Panametrics Aurora Series TDLAS Moisture Analyzers
Aurora

Our industrial TDLAS analyzer,Aurora, provides moisture measurementsfrom2 to 5000 PPM. Its accurate measurement techniquemeasuresmoisture in many applicationssuch as natural gas TEG dehydration, natural gas storage, transmission and custody transfer, carbon dioxide for enhanced oil recovery and carbon sequestration, metal heat-treating furnace gases, and hydrogen recycle gas in reforming. Features include:

Range

  • 0 - 5000 ppm measurement range, for CO2 applications: 0 - 1000 ppm
  • Dew/Frost Point: -97º to 27.3ºF (-71º to -2.6ºC) frost point @ STP of 25ºC, 14.696 psia
  • Absolute Humidity: 0.095 to 237 lbs/MMSFC (1.52 to 3,803 mg/m3)

Accuracy

  • ±1% of reading or ±2 ppm, whichever is greater; for > 1000 ppm, ±5% of reading
  • For CO2 applications: ±3% of reading or ±5 ppmv
  • For H2 recycle applications: ±1% of reading or ±2 ppmv
  • Repeatability: ±0.2 ppmv or ±0.1%, whichever is greater. For CO2 applications: ±1.0 ppmv or ±0.5%, whichever is greater
  • Response Time: Optical system <2 seconds
  • Operating Sample Cell Pressure: 10 to 25 psia (69 to 172 kPa)

Hazardous Area Certifications

  • USA/Canada: Explosion-proof for Class I, Division 1, Groups B, C, D
  • EU and Elsewhere: ATEX and IECEx: Ex de IIB+H2 T6 -20°C to +65°C Flameproof with increased safety compartment
Aurora
Aurora TransPort

A portable industrial TDLAS analyzer, ourPanametrics Aurora TransPortdelivers reliability and accuracy anywhere. This on-the-go moisture analyzer rapidly responds to changes in moisture content in most gases. The unit is assembled intoa rugged and transportable case with a telescoping handle and wheels.

The TransPort isideal for spot-checkingthe performance ofnatural gas processing and drying systems, gas storage facilities, compression stations, refinery processes, heat-treating furnaces, instrument air, and more. It is ideally suited forfield verification of permanently installed moisture analyzers and transmitters. Features include:

Range

  • Calibrated range: 0 to 5000 ppmv. For CO2 applications: 0 to 1000 ppmv
  • Lower detection level: 2 ppmv (-71.7°C). For CO2 applications: 20 ppmv (-55.3°C)
  • 露珠/霜点:过程/等效露水Point/Frost point calculation at user-defined constant pressure or external pressure specified by Modbus

Accuracy

  • Parts per million by volume: ±1% of reading or ±2 ppmv , whichever is greater; for >1000 ppmv ±5% of reading
  • For CO2 applications: ±3% of reading or ±5 ppmv. For H2 recycle applications: ±1% of reading or ±2 ppmv (for up to ±5% H2 and ±1% C2H6 variation from nominal calibration composition) (Individual instrument calibrated accuracy conditions provided in Certificate of Conformance. Accuracy of other parameters derived from ppmv.)
  • Repeatability: ±0.2 ppmv or ±0.1%, whichever is greater. For CO2 applications: ±1.0 ppmv or ±0.5%, whichever is greater
  • Operating sample cell pressure 10 to 25 psia (69 to 172 kPa)

Battery Life

  • Rechargeable battery provides 8 to 10 hours of operation
Aurora Transport
Aurora RM

Panametrics Aurora RMrack-mount analyzer usestunable diode laser absorption spectroscopy (TDLAS)to accurately measure moisture in a variety of background gases. TheAurora RM analyzer is suitable for installation in safe areas andoperatesoverawiderangeofenvironmentalconditions.

AuroraRM’s fast response immediately alerts the user when moistureconcentrationsareoutofcompliance;oncecorrected,gascanbe quickly cleared for process normalization.

Aurora RM

Ultrasonic Flow Meters
Panametrics Success Stories

Check out our latest case studies across multiple industries & applications.

Panametrics webinars
View Our On-Demand Webinars

From moisture measurement to clamp-on flow meters and flare operations - we have an on-demand webinar for you!

Panametrics Services
Need Assistance? Contact Us Today!

A Panametrics expert is ready to listen and assist you.


dark green very small

Featured Industry: Panametrics Refinery Solutions

Produce more at a lower cost, efficiently and safely, with industry-leading Panametrics moisture and gas measurement, flare management, flare measurement and ultrasonic flow metering solutions.

dark green very small

Whitepaper: Moisture analyzers for Hydrogen Recycle & Natural Gas Applications

Learn Moisture Analyzers for Hydrogen Recycle & Natural Gas Applications free in this whitepaper



Get in touch with an expert.

Your request has been submitted.
Thank you for your interest. A specialist will be in touch with you shortly.