Inspect with precision, power, and productivity

The Phoenix V|tome|x M is Waygate Technologies most versatile and precise X-ray microfocus CT cabinet system for 3D metrology and analysis.

This highly productive Dual|tube scanner with its 300 kV microfocus and optional 180 kV nanofocus X-ray tubes delivers improved accuracy at unprecedented speeds—helping you dramatically optimize your lab research results and production quality processes to meet today’s und future increasing demands.



Premium 3D metrology and analysis industrial CT starts here
Phoenix V|tome|x M300
Phoenix V|tome|x M300

Our powerful industrial computer tomography (CT) system, designed for 3D metrology and analysis, providesindustry-leading magnification at 300 kV. It is the世界上第一个microCT扫描仪Scatter|correct technology, to automatically remove scatter artifacts for higher image quality. With a variety of exclusive high performance detectors and proprietary premium CT technologies, the Phoenix V|tome|x M revolutionizes CT inspection and 3D metrology - deliveringfaster scansandhigher throughputs without compromising image quality and measurement precision.

Highlights


Benefits

CT Scanning & Metrology at Higher Accuracy, Higher Speeds

  • High-quality images via Scatter|correct technology
  • High-speed scans thanks to exclusive detectors technology and patented
  • Outstanding reliable metrology precision
  • Highest versatility due to optional 300 kV micro- and 180 kV nanofokus Dual|tube setup
  • Industry-leading microfocus magnification at 300 kV
Applications

The Phoenix V|tome|x M300 system covers an extremely wide range of application capabilities:

  • Internal defect analysis
  • 3D quantitative porosity analysis
  • Assembly control
  • Materials structure analysis for small high-absorbing castings
  • Highest precision nanoCT of small or low absorbing samples
  • Research: 3D printing, composites, battery cells and modules, ceramics, medical industry
  • Precision 3D metrology
  • CAD Data nom/act comparison
Phoenix V|tome|x M Features
Micro- /nanofocus Dual|tube configuration

300 kV / 500 W microfocus X-ray tube - specially optimized for CT applications optionally combined with a high power 180 kV/20 W nanofocus X-ray tube for highest precision scans of smaller and lower absorbing samples

Long-life|filament

Up to 10 times increased filament lifetime, ensuring long-term stability and optimizing system efficiency by Long-life|filament (optionally)

Scatter|correct technology

Waygate Technologies’ exclusive patented Scatter|correct technology enables you to perform highly precise CT scans of highly radiation scattering samples with the superior image quality of fan beam CT at the up to hundred times faster throughput of cone beam CT

Dynamic 41 digital detector

Double CT resolution at the same speed, or double throughput at the same quality level as 200 µm pitch DXR detectors. Compared to 16-bit detectors, the optimized 14-bit technology offers the highest efficiency with a dynamic range of 10000:1 and thus saves time in use and also generates less noise in the image

Helix|CT

Scan with improved image quality to increase probability of detection (POD) with efficiency and ease

Offset|CT

Scan even larger parts with up to~70%larger scanning volume

Orbit|scan

Define a virtual scan rotation axis for ease of scan adjustment and flexible ROI CT scans

Multi|bhc

The Multi|bhc tool corrects streaking artifacts which typically occur as multiple dark streaking bands positioned between dense areas in multi-material samples

Metrology|edition

As part of the optionalMetrology|edition, The Ruby|plate calibration phantom and the compensation of thermal drift effects based on the use of temperature sensors enable automated measurement sequences and precision to a new level of performance for even larger parts. The system guarantees a measurement accuracy of SD ≤ (3.8 ± L/100 mm) µm according to VDI/VDE 2630-1.3 for reliablerevalidation of the system performance and reproducible measurement applicationslike:

  • Nominal-actual CAD comparison
  • Dimensional measurements / wall thickness analysis
  • Reverse Engineering/Tool Compensation
ASC|filter

Adaptive scatter correct filter offering unrivaled image quality by significantly reducing artifacts caused by reduced grey values in high absorbing sample CT datasets

High-flux|target

Improve efficiency with faster microCT scans or doubled resolution with higher power on a smaller focal spot

Sample|changer

This easily removable holder allows automatic change of different samples

Filter|changer

结合示例|改变,选择al Filter|changer allows to perform mixed batch CT scans

Fully automated robot

Maximize speed and accuracy and reduce your operational costs by implementing robot loading into your inspection procedures

Phoenix Datos|x CT software

Fully automate your data acquisition, volume processing, and evaluation with ease

CT inspection and metrology services

Global Industrial X-ray 2D and 3D CT Scanning Services from Waygate Technologies

Key Solution Characteristics
Industry-leading detector performance

The Phoenix V|tome|x M comes standard with ourexclusive4 MP Dynamic 41|200 next-generation photodiodedesign industrial X-ray detector. Itprovides 10x increased sensitivityrelative to the state of the art 200µm pixel-size DXR detectors producing a 2-3x cycle time increase without image quality impact, making inspections and measurements more efficient and productive. As a premium option,the100µm / 16 MP Dynamic 41|100 detectorprovides 2x the resolution increasewithout impacting cycle times. Detection of 2x smaller defects without an increase of geometric magnificationallows for the imaging of large objects at higher resolutions.

Dynamic 41 digital detector technologymeans you get up to2-3x faster CT scansor doubled resolution.

protector
Faster scans with less artifacts

AdvancedScatter|correcttechnologyautomatically removes scatter artifactsfor artifact-free precision CT results onthe quality level of fan-beam CT scanned several hundred times faster with advanced cone-beam CT.

scatter correct turbine blade
Unprecedented scan speed

Our proprietaryHigh-flux|targetallows forhigher power on a smaller focal spot, so you cancut scan time in half.

High-flux|target
Automated CT process

Boost your CT scanning performance with afully automated, robot-based workflowand3D analysis in real-time.

Phoenix Vtomex M robot load CT
Enhanced reliability with real results

由欧r proprietary technology and durable hardware, you canmaintain safe and reliable operations while remaining in compliance.

Optimized inspection performance

By bringing yourCT inspection right onto the factory flooror into the lab, you can unite manufacturing with quality control forgreater reliability, speed, and efficiency.

最大的灵活性

UniqueDual|tube configurationsenhance the flexibility. Depending on the inspection task, fast and easy change between the microfocus and nanofocus X-ray tube is possible just by a push of a button.

phoenix vtomex m easy tube exchange
Precision metrology

WithRuby|plate and True|positiontechnology, the Phoenix V|tome|x M has a specified accuracy of SD ≤ (3.8 + L/100 mm) µm, referring to VDI 2630-1.3 guideline. For all other positions between the VDI positions, a remarkable accuracy of SD ≤ (5.5+ L/100 mm) µm can be reached.

WT_Ruby|plate
AI-based automated defect recognition (ADR)

Proprietary machine learning (ML) based algorithms deliverexceptional Automated Defect Recognition (ADR)across various flaws for e.g. battery anode overhang analysis or typical casting defects. Our AI and data science based ADR library yields greater accuracy and enhanced ease of use compared to conventional ADR approaches,eliminating the need for expert parameterization skills.

Waygate Technologies offersX|approver, the next level and premium ADR platformconsisting of the full and intuitive workflow management as well as a comprehensive ADR library running in the background of your production delivering automatic decision making. On top of it reporting functions are provided to see potential negative trends in production at a glance. Any authorized operator can parametrize scanned samples (e.g. for highly accurate overhang issue detection), and the algorithms get more accurate over time.

battery anode artificial intelligence based CT analysis ADR
Flash! optimized 2D failure detection

There is more information in an images acquired within a 2D application or slide taken from a CT scan visible for the human eye.该系统包括Waygate技术X |行动NDTinspection software with industry leadingFlash!™intelligent image processing technologyunveil details that are not visible before.Users benefit from two versions:

  • Flash! (for general NDT use such as casting inspection)
  • Flash! Electronics (optimized for Electronics inspection)
Flash automotive casting comparison
Get your upgrade!

Want to pimp your system? With our software- and hardware-upgrades, you can increase your quality and throughput. Have a look at your upgrade options by clicking here!

CT metrology lab
Learn About the 3D Metrology 2.0 Upgrade

You can now retrofit your V|tome|x M CT system with the latest metrology 2.0 upgrade package. This upgrade complies with the VDI 2630 standard and enables you to fully benefit from the advantages of CT based metrology.

FAQs
What is the maximum sample weight?

Up to50 kg, depending on the application.

What is the maximum sample diameter and sample height?

Up to500 mm diameterand600 mm in heightwith limited travel range.

What is the maximum 3D scan size?

Up to420 mm diameterand400 mm in height.

Are there upgrade options available for my system?

For the Phoenix V|tome|x M as our premium CT system, there are always latest hard- and software innovations as upgrade options available, helping you to even boost your systems performance.

AutoCT Video

AutoCT: Radiography Inspection with CT

Image Card Radiography Request A Demo
See for yourself

Request a demo

Contact us to schedule your own on-site or virtual demo to discuss your unique application needs and how we can help you deliver peace of mind.


Our videos on demand


工业Volumetric Computed Tomography (VCT) Applications
Video

Redefining Automation for Industrial Volumetric Computed Tomography (VCT) Applications -A world-class example of pushing the limits of lean manufacturing.

Waygate Technologies | Premium CT
Video

Waygate Technologies | Premium CT - Discover even the most minute defects for total confidence in your product quality, without slowing processes down. Innovative PremiumCT systems from Waygate Technologies.

Metrology by CT | Webinar
Video

This webinar gives an introduction to the basics of metrology by CT and discusses the major factors that influence metrological performance.


You might also like


Get in touch with an expert.

Your request has been submitted.
Thank you for your interest. A specialist will be in touch with you shortly.